Skip to main content

Using ATP measurements to rapidly evaluate the cleanliness of spectacle surfaces

Abstract

Objective

Microbial contamination on used spectacles poses a potential health risk to spectacle wearers and people regularly working with worn spectacles, such as opticians. ATP measurement is widely used to evaluate the cleanliness of surfaces based on the detection of adenosine triphosphate, a molecule found in and around living cells. In this study, we investigated the suitability of this method to rapidly and easily evaluate the efficacy of different cleaning methods for spectacles. Additionally, we examined the correlation between ATP content on spectacle surfaces with aerobic and anaerobic bacterial colony counts. We swab-sampled worn spectacles and used an ATP bioluminescence assay to assess the level of cellular contamination.

Results

Six cleaning methods were tested on ten worn spectacles each, and ATP levels were correlated with both aerobic and anaerobic bacterial counts. All investigated cleaning methods showed a significant median reduction of the ATP content on spectacle surfaces, between 75 and 93%. Germ counts and ATP levels showed no significant correlation for aerobic but for anaerobic cultivation. Higher anaerobic germ counts correlated positively with higher ATP levels. ATP measurement is a suitable method to rapidly and easily demonstrate the efficacy of cleaning measures for spectacle surfaces also under non laboratory conditions.

Peer Review reports

Introduction

Surfaces that come into regular contact with the human body typically harbour microorganisms, the majority of which are part of the resident skin and mucosa microbiota. Despite their largely beneficial nature for humans, some these microorganisms still possess pathogenic potential. Hence, such surfaces are classified as fomites [1]. Recent studies have investigated the microbial load and potential health risks associated with frequently touched items, including smartphones [2], hospital surfaces [3] and spectacles [4]. Spectacles, ubiquitous optical devices designed to enhance human vision, are positioned prominently on the face, exposed to the environment and in close contact with skin, nose, and mouth. Their regular handling with human hands further emphasizes their potential for microbial contamination. Despite their widespread use, limited research has been conducted on the microbiota of spectacles, leaving a gap in our understanding of potential microbial presence [4]. In clinical settings, spectacles worn by surgeons were recognized as fomites [5]. In our earlier research, we observed that regular cleaning of spectacles has the potential to significantly reduce the microbial load, with a notable decrease of up to 2 log scales [6]. Notably, impregnated lens wipes emerged as the most effective cleaning method, achieving a median germ reduction between 99 and 100%, while dry cleaning showed less efficacy with median germ reduction ranging from 85 to 90% [4].

Adenosine triphosphate (ATP) measurements have a long tradition to monitor the cleanliness of surfaces in different industry sectors and the field of healthcare [7,8,9]. Although ATP testing has proven to be a highly sensitive method for establishing cleanliness standards in healthcare settings [10], the ATP bioluminescence method is particularly effective for assessing cleaning efficacy and can be integrated into daily clinical practice for routine monitoring. Additionally, it helps identify high-risk surfaces, those prone to rapid re-soiling, and surfaces that are easier to clean [11].

Cultivation of microorganisms is the traditional and widely adopted method for assessing microbial cleanliness and disinfection effectiveness. It is crucial to emphasize that the incubation process for these cultures typically extends over several days [7]. In the last decade, numerous medical institutions such as the US Centers for Disease Control and Prevention (CDCs), and healthcare oversight organizations in China, have increasingly turned to the ATP bioluminescence method to assess surface cleaning and disinfection on-site [12]. The ATP bioluminescence method detects the ATP content in a sample, stemming from living cells, by observing the biological luminescence reaction in a luciferase assay utilizing a luminometer [12].

The amount of ATP is quantified in Relative Light Units (RLU) through the enzymatic conversion of ATP into light. As a result, a high RLU readout indicates cellular contamination, thereby fostering the growth and dissemination of microorganisms [13]. RLU are commonly used to quickly assess surface cleanliness in healthcare and other settings [14]. The ATP bioluminescence method has gained popularity due to its simplicity and rapidity, addressing the delays associated with the colony counting method [12]. Nonetheless, the relationship between the measured ATP levels and microbial contamination within healthcare and other settings is limited, and diverse studies present varying correlations [12, 13, 15,16,17].

In this study, we investigated, for the first time, the potential correlation between ATP content and microbial load on spectacle surfaces. In addition, six different types of widely used spectacle cleaning approaches were assessed for their cleaning efficacy. Overall, our study aimed at establishing ATP measurements as a rapid method for evaluating the microbiological cleanliness of spectacles, which can easily be used by non-experts outside a microbiological laboratory, such as by opticians in an optician’s store or during a trade fair for ophthalmic optics.

Methods

Evaluation of different cleaning methods for spectacles by ATP bioluminescence method

A total of 30 worn spectacles were voluntarily provided by staff and students of Furtwangen University, campus Villingen-Schwenningen. Cleaning tests were performed with half spectacles, including the total area (front and back, respectively) of one lens, nose pad and ear clip, estimated to have a total surface area of 30 cm2. Per cleaning procedure, ten spectacle halves stemming from different spectacles were used, i.e. the sample size was 10 per investigated procedure. ATP measurements were conducted with a Kikkoman Lumitester PD-30 (Kikkoman Biochemifa, Tokyo, Japan), utilizing LuciPac pen swabs (Kikkoman Biochemifa), with results reported in RLU. Based on the study by Bakke [7], 100 fmol of ATP correspond to an RLU value of 174 using this Kikkoman technology. All measurements were performed by the same person following the manufacturer's guidelines. Using sterile swabs yielded RLU values between 0 and 5. Pre-cleaning ATP measurements were carried out with the uncleaned, worn spectacles. Subsequently, the identical area underwent standardized cleaning. After that, post-cleaning ATP measurements were taken. During each cleaning procedure, the respective spectacle surfaces were wiped five times upward and five times downward with the respective cleaning device. For each cleaning, a new device was used.

The study evaluated six different cleaning materials for their effectiveness. The first method involved a dry cotton towel (TW). The second method utilized a soap water (SW) solution, created by mixing 2 drops of regular dishwashing liquid with 2 ml of tap water. This solution was generously applied to all surfaces of the spectacle, followed by standardized wiping with a dry cotton tissue. The third material tested was a dry, finely textured microfiber cloth (MC), while the fourth consisted of dry cotton tissues (DCT), which were cellulose-based and alcohol-free. The fifth method utilized antibacterial wipes (ABW) infused with ethanol and isopropanol, and the sixth used alcohol-free wipes (AFW) containing an amine-based cleaning solution. Except for the soap water solution, all cleaning materials were supplied by Carl Zeiss Vision International GmbH (Aalen, Germany).

Corelation between germ count and ATP content

10 spectacles were provided voluntarily by employees and students of Furtwangen University, campus Villingen-Schwenningen. Each spectacle was divided into two halves, with one half allocated for ATP measurement, while the remaining half was designated for colony counting, assuming no difference in microbial load between the right and left halves. Indeed, small scale analyses indicated no significant differences of the ATP content on the left (150 ± 37.01 RLU/cm2) and right sides (121.66 ± 17.56 RLU/cm2) of 5 worn spectacles. The same was true for the aerobic germ counts (left: 123 ± 34 CFU/cm2, right: 124 ± 54 CFU/cm2) and anaerobic germ counts (left: 77 ± 74 CFU/cm2, right: 160 ± 51 CFU/cm2) obtained with 3 worn spectacles (median ± mean deviation from median). All samplings took place in the university laboratory. ATP measurements were performed as described above. Germ counts were performed as previously reported [4]. In brief, each spectacle half was sampled twice with sterile cotton swabs, first with a wetted swab and then with a dry swab. A sterilized medium containing 1.5 g of casein peptone (Carl Roth, Karlsruhe, Germany) and 12.75 g of sodium chloride (Carl Roth) per 1500 mL of water were utilized for the wet swab. This medium was also used for the subsequent dilution series. After the sampling process, the wet and dry swab heads were combined and vortexed for 10 s in 2 mL of wetting medium to suspend all microbes.

Germ quantities were determined from the suspension through serial dilution up to 10–5, and 50 µL of each dilution was plated in duplicates on Tryptic Soy Agar plates (TSA; Carl Roth), serving as a non-selective medium for bacterial cultivation. The plates were then incubated under aerobic conditions for 3 days at 37 °C. Thioglycolate Agar (Merck, Darmstadt, Germany) was used for bacterial cultivation under anaerobic conditions for a duration of 10 days at 37 °C. The anaerobic cultivation was conducted in an anaerobic jar utilizing an anaerocult with indicators (Merck). Colonies within the range of 30 to 300 per plate were counted. Germ numbers were expressed as colony forming units (CFU) cm −2. Sterility tests showed no growth when an inoculum was absent.

Statistical analysis

To assess the effectiveness of different cleaning methods, median RLU values and mean deviations from the median (MDM) were calculated. The statistical analysis was done using R (version 4.3.0) [18] and R Studio (version 2023.09.1 + 494) [19]. Normal distribution was assessed using the Shapiro–Wilk test. As not all data followed a normal distribution, non-parametric tests were applied. The Mann–Whitney-U test was used to compare pre- and post-cleaning RLU values. The Kruskal–Wallis-H test was conducted to compare the relative reduction of RFU values by the different cleaning techniques. Subsequently, post-hoc pairwise comparisons were conducted. The correlation between RLU and CFU values was calculated using scatterplots and the Pearson correlation coefficient.. Results with adjusted p-values < 0.05 were considered statistically significant.

Results

Effect of different cleaning methods

Table 1 shows the efficacy of the tested cleaning approaches in reducing contamination on spectacles, as measured by ATP levels. The assessment is based on pre- and post-cleaning ATP levels, with percentage-based reduction and corresponding p values providing insights into the efficacy of each method.

Table 1 Effect of different cleaning methods on ATP content as measure for contamination of spectacles

All cleaning methods significantly reduced ATP levels between 75 and 93%, indicating effective cleaning performance. Statistical analysis showed an overall significant difference between the different cleaning methods, when based on relative reduction of ATP level (p = 0.01335). However, pairwise comparisons only revealed that AFW was significantly more effective than both DCT and MC, with p values of 0.03 and 0.04, respectively. No other pairwise comparisons were found to be significant. Nevertheless, formulated as a trend, the observed methods might be grouped into methods showing > 85% reduction (AFW, ABW), 80–85% reduction (DCT, TW, MC) and less than 80% reduction (SW).

Correlation between germ count and ATP content

In Figs. 1 and 2, ATP levels measured in RLU cm−2 and germ counts in CFU cm−2 are plotted against each other.

Fig. 1
figure 1

Scatterplot illustrating the correlation between aerobic germ counts and ATP. The correlation was not significant (p = 0.36). The line of best fit for the data (95% confidence interval) is within the shaded area. R = correlation coefficient

Fig. 2
figure 2

Scatterplot illustrating the correlation between anaerobic germ counts and ATP levels. The correlation was significant (p = 0.025). The line of best fit for the data (95% confidence interval) is within the shaded area. R = correlation coefficient

Figure 1 shows that the aerobic CFU values ranged from a minimum of 40 to a maximum of 160 CFU cm−2, indicating varying levels of aerobic bacterial contamination across different spectacles. Values of the ATP measurements ranged from 66.83 to 115.57 RLU cm−2. The median values were 56 CFU cm−2 for aerobic germ count and 88.22 RLU cm−2 for ATP. The correlation between aerobic CFU and ATP levels was further analysed in the statistical analysis, with a p-value of 0.34 suggesting no corelation.

In Fig. 2 anaerobic germ counts and ATP measurements are presented. Anaerobic CFU values ranged from a minimum of 40 to a maximum of 371 CFU cm−2, showcasing a broad spectrum of anaerobic bacterial contamination. The median was 107 CFU cm−2 for anaerobic germ count. ATP data were as reported above. The correlation between germ counts and ATP levels was found to be significant with a p-value of 0.025.

Discussion

The aim of the study presented here was to investigate the suitability of ATP measurements to demonstrate the efficacy of popular cleaning measures for worn spectacles and to investigate possible correlations between germ counts and ATP content on spectacle surfaces.

Despite its frequent use, an actual correlation between ATP content and microbial contamination could not be proven for all settings [20, 21]. Nevertheless, some researchers previously reported a correlation between ATP and CFU on surfaces [22,23,24,25]. Our data also show a significant correlation between ATP content and anaerobic germ counts. Notably, oxygen-tolerant anaerobes (e.g., cutibacteria) were identified as the most abundant taxa in our previous studies on spectacles [26] and similar surfaces [6], which might explain that only a significant correlation with anaerobic but not with aerobic germ counts was found. In addition, the correlation analysis also might have been influenced by non-microbiological ATP-sources, such as human skin cells or skin-borne ATP. Finally, the aerobic colony count method used here also has some limitations, such as incubation time, temperature and the choice of growth medium [27]. The use of TSA agar plates cultured at 37 °C for 72 h might have discriminated slow-growing microbes, those with more specific nutrient requirements or environmental bacteria with a temperature optimum below 37 °C [13]. This will be considered in follow-up studies. Nevertheless, the observed link between ATP content and germ counts indicates that ATP measurements are suitable to rapidly evaluate the microbiological hygiene status of spectacles surfaces and the efficacy of cleaning measures.

All investigated cleaning techniques lead to a significant reduction of the ATP levels on spectacle surface, indicating that all methods are suitable to improve the hygiene status of spectacles [28]. However, due to the large dispersion of the data and the relatively small number of replicates, there were hardly any significant differences between the six investigated cleaning techniques. In general, the reduction of ATP might be caused by the mechanical removal of cells and ATP molecules from the smooth, and hence easy to clean surfaces, aided by detergents, solvents and antimicrobial actives in the respective products.

The tested non-alcoholic wipes led to significantly better ATP removal than cotton tissue and microfabric cloth. Similar results were obtained in our previous study [4] in which we investigated the removal and inactivation of test bacteria from glass lenses with dry and wet lens wipes. Notably, choosing non-alcoholic, tenside-based products for cleaning spectacles can be regarded beneficial from a technical point of view, as it protects delicate spectacle parts, such as plastic frame material, from potential damage by alcohol [4]. Though not statistically significant, the relatively bad performance of soap water followed by drying with a cotton tissue, was not expected and needs to be validated in further studies, e.g. by improving the cleaning procedure itself. Nevertheless, considering the detergent and antimicrobial properties of soap and it its easy accessibility, also cleaning with soap water can be regraded an effective measure to improve the hygienic status of spectacle surfaces [29].

Conclusion

The microbial load on spectacle surfaces is correlated with its ATP content. ATP measurement can be used as an easy-to-use and rapid method to demonstrate the efficacy of spectacle cleaning measures. It can also be used by non-microbiologists and also under non-laboratory condition, such as in optician’s shops or during a trade fair for ophthalmic optics, to demonstrate the efficacy of (new) cleaning measures. The evaluation of six widely used spectacle cleaning approaches revealed a significant reduction in ATP levels between 75 and 93%, indicating all methods suitable to improve the hygienic status of spectacles. Future research can include additional cleaning methods (such as ultrasonication or UV-C irradiation) and should aim at establishing probably situation-dependent borderlines, which germ counts and ATP contents on spectacle surface are tolerable from a hygienic point of view.

Limitations

Our study has limitations with respect to the small sample size of investigated worn spectacles, which were all stemming from a single environment, i.e., a university environment. In addition, only two cultivation media were used for aerobic and anaerobic cultivation, respectively, which might have hampered the detection and quantification of a broader variety of bacteria. Similarly, only a single ATP detection technology was used. All cleaning tests were standardized and performed by a single person. However, it cannot be excluded that in the hands of other persons, the tested methods might yield different cleaning results. Finally, our data do not provide any thresholds, from which ATP content or microbial load on, spectacle surfaces might be regarded as safe from a hygienic point of view.

Data availability

All data are available from the corresponding author upon reasonable request.

References

  1. Fritz B, Paschko E, Young W, Böhringer D, Wahl S, Ziemssen F, Egert M. Comprehensive compositional analysis of the slit lamp bacteriota. Front Cell Infect Microbiol. 2021;11: 745653. https://doiorg.publicaciones.saludcastillayleon.es/10.3389/fcimb.2021.745653.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  2. Meadow JF, Altrichter AE, Green JL. Mobile phones carry the personal microbiome of their owners. PeerJ. 2014;2: e447. https://doiorg.publicaciones.saludcastillayleon.es/10.7717/peerj.447.

    Article  PubMed  PubMed Central  Google Scholar 

  3. Christoff AP, Sereia AF, Hernandes C, de Oliveira LF. Uncovering the hidden microbiota in hospital and built environments: new approaches and solutions. Exp Biol Med (Maywood). 2019;244(6):534–42. https://doiorg.publicaciones.saludcastillayleon.es/10.1177/1535370218821857.

    Article  CAS  PubMed  Google Scholar 

  4. Fritz B, Jenner A, Wahl S, Lappe C, Zehender A, Horn C, Blessing F, Kohl M, Ziemssen F, Egert M. A view to a kill?-ambient bacterial load of frames and lenses of spectacles and evaluation of different cleaning methods. PLoS ONE. 2018;13(11): e0207238. https://doiorg.publicaciones.saludcastillayleon.es/10.1371/journal.pone.0207238.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  5. Butt U, Saleem U, Yousuf K, El-Bouni T, Chambler A, Eid AS. Infection risk from surgeons’ eyeglasses. J Orthop Surg (Hong Kong). 2012;20(1):75–7. https://doiorg.publicaciones.saludcastillayleon.es/10.1177/230949901202000115.

    Article  PubMed  Google Scholar 

  6. Fritz B, Schäfer K, März M, Wahl S, Ziemssen F, Egert M. Eye-catching microbes-polyphasic analysis of the microbiota on microscope oculars verifies their role as fomites. J Clin Med. 2020. https://doiorg.publicaciones.saludcastillayleon.es/10.3390/jcm9051572.

    Article  PubMed  PubMed Central  Google Scholar 

  7. Bakke M. A comprehensive analysis of atp tests: Practical use and recent progress in the total adenylate test for the effective monitoring of hygiene. J Food Prot. 2022;85(7):1079–95. https://doiorg.publicaciones.saludcastillayleon.es/10.4315/JFP-21-384.

    Article  CAS  PubMed  Google Scholar 

  8. Martínez-Pérez-Cejuela H, Calabretta MM, Bocci V, D’Elia M, Michelini E. Super-stable metal–organic framework (mof)/luciferase paper-sensing platform for rapid atp detection. Biosensors. 2023;13(4):451. https://doiorg.publicaciones.saludcastillayleon.es/10.3390/bios13040451.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  9. Cannon JL, Park GW, Anderson B, Leone C, Chao M, Vinjé J, Fraser AM. Hygienic monitoring in long-term care facilities using atp, crassphage, and human noroviruses to direct environmental surface cleaning. Am J Infect Control. 2022;50(3):289–94. https://doiorg.publicaciones.saludcastillayleon.es/10.1016/j.ajic.2021.11.014.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  10. Whiteley GS, Glasbey TO, Fahey PP. A suggested sampling algorithm for use with ATP testing in cleanliness measurement. Infect Dis Health. 2016;21(4):169–75. https://doiorg.publicaciones.saludcastillayleon.es/10.1016/j.idh.2016.11.003.

    Article  Google Scholar 

  11. Niephaus V, Parohl N, Heiligtag S, Reuter H, Hackler R, Popp W. Can the adenosine triphosphate (atp) bioluminescence assay be used as an indicator for hospital cleaning?—A pilot study. GMS Hyg Infect Control. 2024;19:Doc07. https://doiorg.publicaciones.saludcastillayleon.es/10.3205/dgkh000462.

    Article  PubMed  PubMed Central  Google Scholar 

  12. Xu H, Liang J, Wang Y, Wang B, Zhang T, Liu X, Gong L. Evaluation of different detector types in measurement of ATP bioluminescence compared to colony counting method for measuring bacterial burden of hospital surfaces. PLoS ONE. 2019;14(9): e0221665. https://doiorg.publicaciones.saludcastillayleon.es/10.1371/journal.pone.0221665.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  13. van Arkel A, Willemsen I, Kluytmans J. The correlation between ATP measurement and microbial contamination of inanimate surfaces. Antimicrob Resist Infect Control. 2021;10(1):116. https://doiorg.publicaciones.saludcastillayleon.es/10.1186/s13756-021-00981-0.

    Article  PubMed  PubMed Central  Google Scholar 

  14. Omidbakhsh N, Ahmadpour F, Kenny N. How reliable are ATP bioluminescence meters in assessing decontamination of environmental surfaces in healthcare settings? PLoS ONE. 2014;9(6): e99951. https://doiorg.publicaciones.saludcastillayleon.es/10.1371/journal.pone.0099951.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  15. Aycicek H, Oguz U, Karci K. Comparison of results of atp bioluminescence and traditional hygiene swabbing methods for the determination of surface cleanliness at a hospital kitchen. Int J Hyg Environ Health. 2006;209(2):203–6. https://doiorg.publicaciones.saludcastillayleon.es/10.1016/j.ijheh.2005.09.007.

    Article  CAS  PubMed  Google Scholar 

  16. Sanna T, Dallolio L, Raggi A, Mazzetti M, Lorusso G, Zanni A, Farruggia P, Leoni E. Atp bioluminescence assay for evaluating cleaning practices in operating theatres: applicability and limitations. BMC Infect Dis. 2018;18(1):583. https://doiorg.publicaciones.saludcastillayleon.es/10.1186/s12879-018-3505-y.

    Article  PubMed  PubMed Central  Google Scholar 

  17. Amodio E, Cannova L, Villafrate MR, Merendino AM, Aprea L, Calamusa G. Analytical performance issues. JOEH. 2014;11(2):D23–7. https://doiorg.publicaciones.saludcastillayleon.es/10.1080/15459624.2013.852281.

    Article  CAS  PubMed  Google Scholar 

  18. Team RC. R: A language and environment for statistical computing. Vienna: R Foundation for Statistical Computing; 2023.

    Google Scholar 

  19. Posit T. Rstudio: integrated development environment for r. Boston: RStudio, PBC; 2023.

    Google Scholar 

  20. Ishino N, Miyaji C, Ogata M, Inada M, Nagata M, Shimamoto M. Applicability of the ATP assay in monitoring the cleanliness of hospital environments. Infect Dis Health. 2024;29(1):32–8. https://doiorg.publicaciones.saludcastillayleon.es/10.1016/j.idh.2023.09.034.

    Article  PubMed  Google Scholar 

  21. Santos-Junior AG, Ferreira AM, Frota OP, Rigotti MA, Barcelos LDS, Lopes de Sousa AF, de Andrade D, Guerra OG. Effectiveness of surface cleaning and disinfection in a Brazilian healthcare facility. Open Nurs J. 2018;12:36–44. https://doiorg.publicaciones.saludcastillayleon.es/10.2174/1874434601812010036.

    Article  PubMed  PubMed Central  Google Scholar 

  22. Turner DE, Daugherity EK, Altier C, Maurer KJ. Efficacy and limitations of an ATP-based monitoring system. J Am Assoc Lab Anim Sci. 2010;49(2):190–5.

    CAS  PubMed  PubMed Central  Google Scholar 

  23. Anderson RE, Young V, Stewart M, Robertson C, Dancer SJ. Cleanliness audit of clinical surfaces and equipment: who cleans what? J Hosp Infect. 2011;78(3):178–81. https://doiorg.publicaciones.saludcastillayleon.es/10.1016/j.jhin.2011.01.030.

    Article  CAS  PubMed  Google Scholar 

  24. Leon MB, Albrecht JA. Comparison of adenosine triphosphate (ATP) bioluminescence and aerobic plate counts (APC) on plastic cutting boards. J Foodserv. 2007;18(4):145–52. https://doiorg.publicaciones.saludcastillayleon.es/10.1111/j.1745-4506.2007.00060.x.

    Article  Google Scholar 

  25. Chen FC, Godwin SL. Comparison of a rapid atp bioluminescence assay and standard plate count methods for assessing microbial contamination of consumers’ refrigerators. J Food Prot. 2006;69(10):2534–8. https://doiorg.publicaciones.saludcastillayleon.es/10.4315/0362-028X-69.10.2534.

    Article  CAS  PubMed  Google Scholar 

  26. Fritz B, März M, Weis S, Wahl S, Ziemssen F, Egert M. Site-specific molecular analysis of the bacteriota on worn spectacles. Sci Rep. 2020;10(1):5577. https://doiorg.publicaciones.saludcastillayleon.es/10.1038/s41598-020-62186-6.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  27. Olsen RA, Bakken LR. Viability of soil bacteria: Optimization of plate-counting technique and comparison between total counts and plate counts within different size groups. Microb Ecol. 1987;13(1):59–74. https://doiorg.publicaciones.saludcastillayleon.es/10.1007/BF02014963.

    Article  CAS  PubMed  Google Scholar 

  28. Casini B, Tuvo B, Totaro M, Aquino F, Baggiani A, Privitera G. Evaluation of the cleaning procedure efficacy in prevention of nosocomial infections in healthcare facilities using cultural method associated with high sensitivity luminometer for ATP detection. Pathogens. 2018. https://doiorg.publicaciones.saludcastillayleon.es/10.3390/pathogens7030071.

    Article  PubMed  PubMed Central  Google Scholar 

  29. Bhat R, Prajna, Menezez VP, Shetty PR. Antimicrobial activities of soap and detergents. 2012. https://api.semanticscholar.org/CorpusID:212606335. Accessed 9 May 2025.

Download references

Acknowledgements

The authors express their gratitude to all participants who contributed their spectacles for the experiments.

Funding

Open Access funding enabled and organized by Projekt DEAL. This project received funding from a grant provided by the German Federal Ministry of Education and Research BMBF, project CoHMed—Connected Health in Medical Mountains; subproject ‘PersonaMed-B’, grant number 13FH5I09IA.

Author information

Authors and Affiliations

Authors

Contributions

Conceptualization: ME Methodology: NSL, BF, ME Formal analysis: NSL Investigation: NSL, BF Writing – original draft: NSL, ME Writing – review & editing: SW, ME Funding acquisition: ME Resources: SW, ME Supervision: ME.

Corresponding author

Correspondence to Markus Egert.

Ethics declarations

Ethics approval and consent to participate

Not applicable.

Consent for publication

Not applicable.

Competing interests

The authors declare no competing interests.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Sultana Lupin, N., Fritz, B., Wahl, S. et al. Using ATP measurements to rapidly evaluate the cleanliness of spectacle surfaces. BMC Res Notes 18, 216 (2025). https://doiorg.publicaciones.saludcastillayleon.es/10.1186/s13104-025-07282-4

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doiorg.publicaciones.saludcastillayleon.es/10.1186/s13104-025-07282-4

Keywords